Diana Hodgins, J Orthop Trauma Surg Rel Res 2018, Volume 13

Changing the care pathway for hip and knee replacement patients

P

eople with late stage hip or knee osteoarthritis may receive a joint replacement to relieve pain and improve mobility. The

operation is considered a success, with regard to patient reported outcomes. However, studies using GaitSmart on hip and

knee replacement patients one year post op show that less than 50% return to a normal gait and that these gait deficiencies can

result in osteoarthritis in other joints, poor mobility and even falls if not corrected. People adapt their gait due to pain in the

arthritic joint. Once the joint pain is gone, the patient needs retraining to walk correctly and weakened muscles strengthened.

The current care pathway provides patients with physiotherapy for up to 6 weeks post op, guiding the patient to move the joint

and become mobile. However, as it takes 10 weeks for the process of muscle strengthening to start, patients are signed off before

gait retraining can really start. Patients are unaware of how they have adapted their gait; for example, excessive medial-lateral

movement of the thigh i.e. swinging the leg around the body rather than under the body. Therefore, the walking pattern remains

the same, loading other joints incorrectly and poor use of their muscles. This paper proposes a new care pathway for patients,

where gait kinematics is measured in the outpatient clinic using inertial sensors. A report describing the gait deficiency and the

severity, using simple traffic light coding, together with a personalized exercise program is provided to the patient at the end of

their 15 minute session. Tests performed at 6, 12, 24 and 52 weeks post op monitor progress and allow the exercises to become

more demanding as the patient improves. Evidence of the clinical efficacy of this approach will be presented.

Biography

Diana Hodgins has obtained her degree in Mechanical Engineering and her PhD in Solid State Gyroscopes from the University of Hertfordshire (UH). She has 30 patents

granted on solid state sensors and more recently on medical applications relating to the use of these sensors. In 2000 she was awarded an MBE for services to SMEs in the

region and in 2002 she won the Women Inventor of the Year Award for Industry. In 2005 she was awarded an Honorary Doctorate from the UH for services to innovation.

dmh@etb.co.uk

Diana Hodgins

European Technology for Business Holdings Ltd, UK